Leading Edge Features On a Tight Budget

 

APPA 80

  • 3400 count digital display

  • 70 segments analog bar graph

  • Autoranging and manual selection

  • 0.5% basic DCV accuracy

  • Data Hold

  • Auto Power Off

  • Shock proof from 4 feet drops

  • Protective Holster and tilt Stand

  • CAT. III 600V/CAT. II 1000V Safety Standard

APPA 82/82R(True -RMS reading)


  • 4000 count digital display

  • 82 segments analog bar graph

  • Autoranging and manual selection

  • True RMS reading or AC mode (82R)

  • 0.5% basic DCV accuracy

  • Data Hold

  • Frequency Counter

  • Capacitance Measurement

  • Hz reading on AC mode

  • Auto Power Off

  • Shock proof from 4 feet drops

  • Protective Holster and tilt Stand

  • CAT. III 600V/CAT. II 1000V Safety Standard


Specifications : (All at 23oC+- 5ooC< 80%RH)
APPA 80 SERIES MULTIMETER
APPA 80
APPA 82/82R
DCV:


Ranges:
Resolution:
Basic Accuracy:

300.0mV ~ 1000V
0.1mV
(0.5%+ 2d)
400.0mV ~ 1000V
0.1mV
(0.5%+ 2d)
ACV:



Ranges:
Resolution:
Basic Accuracy:
Bandwidth:
3.000V ~ 750V
1mV
(1.50%+ 5d)
40Hz ~ 500Hz
400.0mV ~ 750V
0.1mV
(1.30%+ 5d)
40Hz ~ 500Hz
DCA:


Ranges:
Resolution:
Basic Accuracy:
300.0A ~ 10A
0.1
A
(1.70%+ 2d)
400.0A ~ 10A
0.1
A
(1.70%+ 2d)
ACA:



Ranges:
Resolution:
Basic Accuracy:
Bandwidth:
300.0A ~ 10A
0.1
A
(2.2%+ 5d)
40Hz ~ 500Hz
400.0A ~ 10A
0.1
A
(1.7%+ 5d)
40Hz to 500Hz
:


Ranges:
Resolution:
Basic Accuracy:
300.0 ~ 30.00M
0.1

(0.75%+2d)
400.0 ~ 40.00M
0.1

(0.75%+2d)
Diode Test:


Max Test Current:
Open Circuit Voltage:
Input Protection:
1.5mA
3V
600Vrms
1.5mA
3V
600Vrms
Contiuity Test:


Continuity Threshold:
Continuity Indicator:
Input Protection:
Approx. 30
2KHz Tone Buzzer
600Vrms
Approx. 30
2KHz Tone Buzzer
600Vrms
Hz:


Ranges:
Resolution:
Basic Accuracy:
NA
4KHz ~ 40MHz
1Hz
(0.01%+1d)
Capacitance:


Ranges:
Resolution:
Basic Accuracy:
NA
4nF ~ 40mF
1pF
(2%+8d)
~ Hz:



Ranges:
Sensitivity:
Resolution:
Basic Accuracy:
NA
40Hz ~ 1KHz
1/10 of full scale range
1Hz
(0.01%+5d)

General specifications :
 
APPA 80
APPA 82/82R
Display
3400 count
4000 count
Analog Bar graph Display
70 segments bar graph
82 segments bar graph
Overload Indication
"OL" or "-OL"
"OL" or "-OL"
Sampling Rate
2 times/sec
2 times/sec
Low Battery Indication
Auto Power Off
Approx. 10 minutes
Approx. 30 minutes
Operating Temperature: 0oC to 50oC
Storage Temperature:
-20oC to 60oC, 0 to 80% R.H.
Temperature Coefficient:
0.15 x ( Spec. Acc'y)/oC, <18oC, >28oC
Safety:
IEC 61010& designed to meet UL3111-1
CAT. III 600V/CAT. II 1000V
CAT. III 600V/CAT. II 1000V.
Power Requirement:
IEC LR03, AM4 or AAA size 1.5V x 2.
(82)IEC LR03, AM4 or AAA size 1.5V x 2.
(82R)
Standard 9V battery NEDA 1604, IEC6F22, JIS006P.
Battery Life:
Alkaline 500 hours
Alkaline 300 hours.
Size ( W x L x H ):
85mm x 117mm x 38mm
85mm x 117mm x 38mm
Weight: In grams (with holster
400
400, (82R) 430
Accessories:
Test leads, ZnC battery (installed),
 and manual.
Test leads, ZnC battery (installed),
 and manual.

                               Specifications subject to change without notice.